ESP8266 ESP-01 Remote Wireless Module WIFI to UART Module
AT+CWQAP
AT+CWQAP;Exit links with AP |
||
Testing Instruction: AT+CWQAP=? |
response |
OK |
illustrated |
None |
|
execute instruction: AT+CWQAP |
response |
OK |
illustrated |
None |
AT+CWSAP
AT+CWSAP Setting up the AP mode parameters |
||
test instruction |
response |
|
illustrated |
|
|
Queries instruction: AT+CWSAP? |
response |
Returns the current AP parameters +CWSAP;<ssid>,<pwd>,<chl>,<ecn> |
illustrated |
None |
|
setup instruction: AP+CWSAP= <ssid>,<pwd>,<chl>,<ecn> |
response |
OK Or EPPOR |
illustrated |
instruction parameters: <ssid>string parameter,Access Point Name. <pwd>string parameter,Password up to 64 bytes ASCII <chl>Channel Number <ecn>cipher mode 0 OPEN 1 WEP 2 WPA_PSK 3 WPA2_PSK 4 WPA_WPA2_PSK
|
|
illustrated |
This set of instructions is only effective after AP mode to open |
TCP/IP toolkit AT command
Command |
Description |
AT+CIPSTATUS |
Get the connection status |
AT+CIPSTART |
To establish a TCP connection or registered UDP port number |
AT+CIPSEND |
send data |
AT+CIPCLOSE |
Close TCP or UDP |
AT+CIFSR |
Get the local IP address |
AT+CIPMUX |
Start multiple connections |
AT+CIPSERVER |
Configured as a server |
AT+CIPSTATUS
AT+CIPSTATUS Get the connection status |
||
Testing Instruction |
response |
OK |
illustrated |
None |
|
Executes Instruction AT+CIPSTATUS |
response |
Returns the current module connection state and connection parameters STATUS:<stat> +CIPSTATUS;<id>,<type>,<addr>,<port>,<stat> OK
|
illustrated |
Response Value Description: <id> connection id number 0-4 <type>string parameter,type TCP or UDP <addr>string parameter,IP address <port>Port Number |
AT+CIPSTART
AT+CIPSTART To establish a TCP connection or registered UDP port number |
||
Testing Instruction AT+CIPSTART=?
|
response |
+CIPSTART:(<type>A list of values ),(<IP address>Range),(<port>Range) OK |
illustrated |
None |
|
Set command (+CIPMUX=0) AT+CIPSTART= <type>,<addr>,<port>
(+CIPMUX=1) AT+CIPSTART= <id><type>,<addr>, <port>
|
response |
OK-Format correct and the connection is successful Or ERROR- Failure Or ALREAY CONNECT,Connection has been
|
illustrated |
Command parameters: <id>0-4 connection id number <type>string parameter,Indicates that the connection type,”TCP” established tcp connection . “udp” established UDP connection . <addr>string parameter,The remote server IP address. <port>Remote server port number
|
|
illustrated |
No. 0 connections can dient or server connections, the other can only be used to connect to a remote server id |
AT+CIPSEND
AT+CIPSEND send data |
||
Testing Instruction: AT+CIPSEND=? |
response |
OK |
illustrated |
None |
|
setup instructions: (+CIPMUX=0) AT+CIPSTART=<lenght>
2)Multiple connections (+CIPMUX=1) AT+CIPSTART= <id>,<lenght>
|
response |
Response Returns the specified length of data. After receiving the instruction to wrap return ">", and then begin to receive serial data, send data when the data length full lenght. If you do not establish a connection or connection is disconnected, return ERROR. if the data is sent successfully,return to SEND OK. |
illustrated |
instruction parameters: <id>Required for the transport connection id number. <lenght>numeric argument,Indicates that the length of the send data
|
AT+CIPCLOSE
AT+CIPCLOSE Close TCP or UDP |
||
Testing Instruction: AT+CIPCLOSE=? |
response |
OK |
illustrated |
None |
|
Set command: Multiple connections AT+CIPCLOSE=<id>
|
response |
If the input is correct, return OK Without the connection, returns the Link is not If you turn off No. 0 connection, and the connection for the server, it returns Cant close (closed 0 need to restart the server connection) |
illustrated |
command parameter: <id>Need to close the connection id |
|
Executes Instruction: AT+CIPCLOSE |
response |
If the input is correct, return OK Without the connection, returns the ERROR If you want to shut down the server, it returns we must restart (connection need to restart) |
illustrated |
None |
|
illustrated |
Closed state is unlink |
AT+CIFSR
AT+CIFSR Get the local IP address |
||
Testing Instruction: AT+CIFSR=? |
response |
OK |
illustrated |
None |
|
Executes Instruction: AT+CIFSR
|
response |
+CIFSR:<IP address> OK Or ERROR |
illustrated |
return response: <IP address>-The current IP address of the machine(station) |
AT+CIPMUX
AT+CIPMUX Start multiple connections |
||
query directives: AT+CIPMUX?
|
response |
+CIPMUX:<mode> OK |
illustrated |
None |
|
Set command: AT+CIPMUX=<mode>
|
response |
OK If you already are connected, it returns Link is builded
|
illustrated |
command parameter <mode> 0 single way connection mode 1 Multiple connection mode
|
|
Executes Instruction |
response |
None |
illustrated |
None |
AT+CIPSERVER
AT+CIPSERVER Configured as a server |
||
Executes Instruction AT+CIPSERVER= <mode>[,<port>]
|
response |
Automatically create a server monitor server after opening OK If 0 connection being used, it returns the Link is builded Close need to restart the server
|
illustrated |
command parameter: <mode> 0 Close the server mode 1 Open the server mode <Port> port number, the default value is 333 |
Classification |
instruction format |
command function |
TEST command |
AT+<X>=? |
This command is used to query or set command to set the parameters of the internal procedures and its value range. |
Query command |
AT+<X>? |
This command returns the current value of the parameter. |
Set command |
AT+<X>=<...> |
This command is used to set the user custom parameter values. |
Execute Command |
AT+<X> |
This command is used by the module to perform internal program control functions varying parameters immutable. |
Command |
Description |
AT+RST |
Restart the module |
AT+RST
AT+RST Restart the module |
||
Execute Command:
AT+RST |
response |
OK |
illustrated |
None |
Video Demo:
Quantity | 5+ |
Price | $2.35 |
Tested by Our Partner PDAControl:
ICStation doesn't accept any form of pay on delivery. Items used to be shipped after payment. Below are the payment methods we can accept at the moment:
1) Paypal Payment
PayPal is a secure and trusted payment processing service that allows you to shop online. PayPal can be used at icstation.com to purchase items by Credit Card (Visa, MasterCard, Discover, and American Express), Debit Card , or E-check (i.e. using your regular Bank Account).
We are PayPal Verified
2) Bank Transfer / Wire Transfer / T/T
Bank Transfer / Wire Transfer / T/T payment methods are accepted for orders which the total price is up to US$300. The bank will charge about US$50 for the transfer fee if we do the payment in these ways. Feel free to contact us for bank payment details if you need pay via bank.
For other payment method, please contact us at orders@icstation-team.com for more details.