Module introduction:
1>.Working voltage: 4.5-5.5V VCC: Connected to the positive pole of the power supply GND: Connected to the negative pole of the power supply
2>.Working current: about 75mA (relay pull-in state)
3>.Static working current: about 6mA (relay release state)
5>.Module type: Infrared 1-channel learning type (can learn all NEC format infrared remote control)
6>.Receiving distance: 5-12 meters (straight line distance, the remote control is aligned with the receiving head; there is no obstacle in the middle)
7>.Working mode: self-locking, jogging, interlocking 3 working modes (module is passive output, output is only used as contact switch mechanical switch)
8>.Work instructions: D3 (power indicator), D6 (relay switch indicator), D6 (learning indicator)
9>.Module size:51*26*18mm
Instructions:
1>.Self-lock mode:
After power-on, press and hold the button S1 on the module, the indicator light D4 flashes 1 time, then release the button, then press the remote control button that needs to be learned; the module D4 indicator flashes 3 times and does not flash. At this time, the remote control button is successfully learned, and the module is automatically set to the self-lock mode.
2>.Jog mode:
After power-on, press and hold the button S1 on the module, the indicator light D4 flashes 2 times, then release the button, then press the remote control button that needs to be learned; the module D4 indicator flashes 3 times and does not flash. At this time, the remote control button is successfully learned, and the module is automatically set to the jog mode.
3>.Interlock mode:
After power-on, press and hold the button S1 on the module, the indicator light D4 flashes 3 times, then release the button, then press the remote control button that needs to be learned; the module D4 indicator flashes 3 times and does not flash. At this time, the remote control button is successfully learned, and the module is set to be able to be turned on or off.
After power-on, press and hold the button S1 on the module, the indicator light D4 flashes 4 times, then release the button, and then press and hold the remote controller that needs to be learned. Button; module D4 indicator flashes 3 times and does not flash; at this time, the remote control button is successfully learned, and the module is set to only turn off and can not be turned on; thus achieving the function of one button to open a button.
4>.Clear operation instructions:
After power-on, press and hold the button S1 on the module, the indicator light D4 flashes 5 times, then release the button; the module is cleared.
ICStation doesn't accept any form of pay on delivery. Items used to be shipped after payment. Below are the payment methods we can accept at the moment:
1) Paypal Payment
PayPal is a secure and trusted payment processing service that allows you to shop online. PayPal can be used at icstation.com to purchase items by Credit Card (Visa, MasterCard, Discover, and American Express), Debit Card , or E-check (i.e. using your regular Bank Account).
We are PayPal Verified
2) Bank Transfer / Wire Transfer / T/T
Bank Transfer / Wire Transfer / T/T payment methods are accepted for orders which the total price is up to US$300. The bank will charge about US$50 for the transfer fee if we do the payment in these ways. Feel free to contact us for bank payment details if you need pay via bank.
For other payment method, please contact us at orders@icstation-team.com for more details.