Categories
1.Description:
It is a 5V Delay Relay Module with Edge-Triggered Control and Loop Cycle for Seamless Switching
2.Parameter:
1>.Power supply: DC 5V
2>.Input signal: High-level (PNP), Low-level (NPN)
3>.Trigger logic: Pulse (width detection), Edge (counting)
4>.Output actions: Close, Open, Toggle, Counted Toggle
5>.Load: 10A current, Normally Closed (NC), Normally Open (NO)
6>.Timers: Two timers with a range of 0.01-999 minutes
7>.Display: Four-digit seven-segment display
8>.Communication: Parameter storage and power-down retention through TTL serial port
9>.Size: 64*50mm
3.Function Setting:
1>.Upon powering on the module, long-press the menu button for 1 second to enter Setting 1, displayed as (P-XX). Short-press the up/down buttons to select the output mode.
2>.Short-press the confirm button to enter Setting 2, displayed as (nX.XX). Short-press the up/down buttons to adjust the relay activation time.
3>.Short-press the confirm button to enter Setting 3, displayed as (FX.XX). Short-press the up/down buttons to adjust the relay reset time.
4>.Short-press the confirm button to enter Setting 4, displayed as (LX.XX). Short-press the up/down buttons to adjust the value (pressing the menu button cycles through the setting positions).
5>.Short-press the confirm button to enter Setting 5, displayed as (rXXX). Short-press the up/down buttons to adjust the value. Short-press the confirm button to save the settings.
4.Auxiliary Setting:
1>.When the module is powered on, it enters the standby mode and displays (P-XX) for the current mode. After a signal trigger, it enters the working state and displays the countdown. During the working state, short-press the confirm button to pause, and short-press again to resume.
2>.In Setting 1 mode, long-press the menu button for 1 second to enter Setting 0, displayed as (A-XX). Short-press the up/down buttons to adjust whether to restore factory settings. Press the confirm button to save the settings. The module will restart.
3>.In Setting 1 mode, long-press the confirm button to turn off the display (d-oF), and long-press again to turn on the display (d-on). (Setting to turn off the display will automatically turn off after 60 seconds of power-on, and any key press will wake it up).
4>.The setting interface will exit if there is no operation for 120 seconds.
5.Package:
1pcs 5V Delay Relay Module
ICStation doesn't accept any form of pay on delivery. Items used to be shipped after payment. Below are the payment methods we can accept at the moment:
1) Paypal Payment
PayPal is a secure and trusted payment processing service that allows you to shop online. PayPal can be used at icstation.com to purchase items by Credit Card (Visa, MasterCard, Discover, and American Express), Debit Card , or E-check (i.e. using your regular Bank Account).
We are PayPal Verified
2) Bank Transfer / Wire Transfer / T/T
Bank Transfer / Wire Transfer / T/T payment methods are accepted for orders which the total price is up to US$300. The bank will charge about US$50 for the transfer fee if we do the payment in these ways. Feel free to contact us for bank payment details if you need pay via bank.
For other payment method, please contact us at orders@icstation-team.com for more details.