Home > Sensor Module > Temperature Module > DC 12V Digital Temperature Controller Module Switch Temp Control Board -9~99 Celsius with Waterproof NTC Sensor Probe
1>. Adopt high-speed MCU, accurate intelligent control
2>. Three vision window display
3>. Simple setting, easy to operate
4>. Wide setting range of -9~99 Celsius
5>. Widely applied to room temperature control, water temperature control, incubators etc
Using Method:
Connect the power supply and device, then it can offer power to the controller; and it will display measured temperature in this time, users can set START to STOP according to their needs
The temperature controller output is 10A relay, it can satisfy various high power loads; after connect the circuit, it can supply power for the controller
START Indicator And Digital Tube Introduction
START Indicator: START (the right side) indicator lamp is on, it means the relay and device starts operating
STOP Indicator: STOP (the left side) indicator lamp is on, it means the relay is disconnected and the device stops operating
Digital Tube: the red digital tube display is measured temperature (left green digital tube is setting start temperature; right green digital tube is setting stop temperature)
Key:
Start: “▲▼” set start temperature
Stop: “▲▼”set stop temperature
High-Temperature Start- refrigeration mode:
When the setting start temperature>stop temperature, detection temperature>=start temperature, the relay will operate, and refrigeration device will operate; when detection temperature <=stop temperature, the relay will be disconnected and the refrigeration device will stop operating. For example, set start temperature is 30 Celsius, stop temperature is 25 Celsius, when the detection temperature is no lower than 30 Celsius, the relay will operate and the START indicator lamp (red) will be on; when the detection temperature is no higher than 25 Celsius, the relay will be disconnected and the STOP indicator lamp (red) will be on
Low Temperature Start-Heating Mode:
When the setting start temperature<stop temperature, detection temperature<=start temperature, the relay will operate, and refrigeration device will operate; when detection temperature >=stop temperature, the relay will be disconnected and the refrigeration device will stop operating. For example, set start temperature is 25 Celsius, stop temperature is 30 Celsius, when the detection temperature is no higher than 25 Celsius, the relay will operate and the START indicator lamp (red) will be on; when the detection temperature is no lower than 30 Celsius, the relay will be disconnected and the STOP indicator lamp (red) will be on
Pin Definition:
Module Size:
Tested by ICStation's Outstanding Partner LearningZone:
ICStation doesn't accept any form of pay on delivery. Items used to be shipped after payment. Below are the payment methods we can accept at the moment:
1) Paypal Payment
PayPal is a secure and trusted payment processing service that allows you to shop online. PayPal can be used at icstation.com to purchase items by Credit Card (Visa, MasterCard, Discover, and American Express), Debit Card , or E-check (i.e. using your regular Bank Account).
We are PayPal Verified
2) Bank Transfer / Wire Transfer / T/T
Bank Transfer / Wire Transfer / T/T payment methods are accepted for orders which the total price is up to US$300. The bank will charge about US$50 for the transfer fee if we do the payment in these ways. Feel free to contact us for bank payment details if you need pay via bank.
For other payment method, please contact us at orders@icstation-team.com for more details.