XH-M452 use ST controller and high-precision temperature sensor probe.Good performance and accuracy.Simple panel control, wide temperature range, simple design, elegant appearance, high mechanical strength. It can be embedded industrial equipment, convenient and fast. It can be used for hatch control, equipment cabinet, air conditioning system, temperature control protection, etc.
Features:
1>. Supports heating mode and cooling mode.
2>. High precision 0.1 Celsius and 0.1%RH.
3>. Real-time display of temperature and humidity.
4>. Custom load, arbitrarily selected.
5>. Simple setting.
6>. Easy installation.
7>. Power-down memory function.
Parameters:
No. | Parameter | Value |
1 | Mode | XH-M452 |
2 | Input voltage | DC 12V |
3 | Temperature range | -20~60Celsius |
4 | Humidity range | 00%-100%RH |
5 | Detection accuracy | 0.1Celsius 0.1%RH |
6 | Detection accuracy | 0.1Celsius |
7 | Sensor | 1Meter Temperature and humidity sensor |
8 | Output Type | Relay Output(Switch Output) |
9 | Size | 65*55*28mm |
Key Description:
1>. ‘Tempearture +’ : Short press to display start temperature;Long press to set start temperature by key ‘Tempearture +’ and ‘Tempearture -’ and display will flashing.It will save automatically after 5second .(Long press is for 3second).
2>. ‘Tempearture -’ : Short press to display stop temperature;Long press to set stop temperature by key ‘Tempearture +’ and ‘Tempearture -’ and display will flashing.It will save automatically after 5second .(Long press is for 3second).
3>. ‘Humidity +’ : Short press to display start humidity;Long press to set start humidity by key ‘Humidity +’ and ‘Humidity -’ and display will flashing.It will save automatically after 5second .(Long press is for 3second).
4>. ‘Humidity -’ : Short press to display stop humidity;Long press to set stop humidity by key ‘Humidity +’ and ‘Humidity -’ and display will flashing.It will save automatically after 5second .(Long press is for 3second).
5>. Note: Restore factory settings if keep press ‘Tempearture -’ and ‘Humidity +’ untill two screen flashing and display ‘888 888’ at the time.
Temperature Control:
1>. Set Start Temperature: Long press ‘Tempearture +’ to set start temperature by key ‘Tempearture +’ and ‘Tempearture -’ and display will flashing.It will save automatically after 5second and then display current actual temperature.
2>. Set Stop Temperature: Long press ‘Tempearture -’ to set stop temperature by key ‘Tempearture +’ and ‘Tempearture -’ and display will flashing.It will save automatically after 5second and then display current actual temperature.
3>. Automatic mode selection:
It is Heating mode if Start Temperature is lower than Stop Temperature.
It is Cooling mode if Start Temperature is higher than Stop Temperature.
4>. Set Steps:
Focus:
Start Temp < Stop Temp (Heating mode,Automatic judgment)
Start Temp > Stop Temp (Cooling mode,Automatic judgment)
Method: Please refer to Set Start/Stop Temperature.
Heating mode example: Control water heater.Heated to 65Celsius and then stop heating.Reheat when the temperature drops to 50Celsius.
Step 1 : Set Heating mode,Start Temp < Stop Temp.
Step 2 : Long press ‘Tempearture +’ and Start Temp flashing.Set Start Temperature to 50Celsius by ‘Tempearture +’ and ‘Tempearture -’.
Step 3 : Long press ‘Tempearture -’ and Stop Temp flashing.Set Stop Temperature to 65Celsius by ‘Tempearture +’ and ‘Tempearture -’.
Cooling mode example: Control farms. Stop ventilation when temperature is 26Celsius.Refrigeration again when the temperature rises to 30Celsius.
Step 1 : Set Cooling mode,Start Temp > Stop Temp.
Step 2 : Long press ‘Tempearture +’ and Start Temp flashing.Set Start Temperature to 30Celsius by ‘Tempearture +’ and ‘Tempearture -’.
Step 3 : Long press ‘Tempearture -’ and Stop Temp flashing.Set Stop Temperature to 26Celsius by ‘Tempearture +’ and ‘Tempearture -’.
NOTE: Indicator will OFF and Load will not work If the temperature is set incorrectly.So please check if Start Temp and Stop Temp are right after set.
Humidity Control:
1>. Set Start Humidity : Long press ‘Humidity+’ to set start humidity by key ‘Humidity+’ and ‘Humidity-’ and display will flashing.It will save automatically after 5second and then display current actual humidity .
2>. Set Stop Humidity : Long press ‘Humidity-’ to set stop humidity by key ‘Humidity+’ and ‘Humidity-’ and display will flashing.It will save automatically after 5second and then display current actual humidity .
3>. Automatic mode selection :
It is Humidification mode if Start Humidity is lower than Stop Humidity.
It is Dehumidify mode if Start Humidity is higher than Stop Humidity.
4>. Humidification mode example: Fresh storage humidification, control humidifier 50% RH to begin humidification, humidify to 80% RH stop.
Step 1 : Set Humidification mode,Start Hum< Stop Hum.
Step 2 : Long press ‘Humidity+’ and Start Hum flashing.Set Start Humidity to 50%RH by ‘Humidity+’ and ‘Humidity-’.
Step 3 : Long press ‘Humidity-’ and Stop Hum flashing.Set Stop Humidity to 80%RH by ‘Humidity+’ and ‘Humidity-’.
5>. Dehumidify mode example: Dehumidification control system in the workshop, humidity 70% RH starts dehumidification, humidity 40% RH stops dehumidification.
Step 1 : Set Humidification mode,Start Hum> Stop Hum.
Step 2 : Long press ‘Humidity+’ and Start Hum flashing.Set Start Humidity to 70%RH by ‘Humidity+’ and ‘Humidity-’.
Step 3 : Long press ‘Humidity-’ and Stop Hum flashing.Set Stop Humidity to 40%RH by ‘Humidity+’ and ‘Humidity-’.
Application:
1>. Hatch control
2>. Equipment cabinet
3>. Air conditioning system
4>. Temperature control protection
5>. Refrigerator
6>. Freezer
7>. Water heater
8>. Hosts
9>. Printing factory
10>. Tobacco industry
11>. Hatchery control
Frequency asked questions:
Q1>. How to restore factory settings?
A: Keep press ‘Tempearture -’ and ‘Humidity +’ untill two screen flashing and display ‘888 888’ at the time.
Q2>. Why display ‘LLL’?
A : Sensor failure, please test the sensor or replace the sensor.
Q3>. Why display ‘HHH’?
A : Test temperature exceeds the measurement range, please replace the use of the environment.
Q4>. Why the indicator does not work and the load does not work?
A : Please check if Start Temp and Stop Temp are right.
Illustration:
Tested by ICStation's Outstanding Partner arduinoLab:
Learn More Details in the Video:
(The language in the video is Russian)
ICStation doesn't accept any form of pay on delivery. Items used to be shipped after payment. Below are the payment methods we can accept at the moment:
1) Paypal Payment
PayPal is a secure and trusted payment processing service that allows you to shop online. PayPal can be used at icstation.com to purchase items by Credit Card (Visa, MasterCard, Discover, and American Express), Debit Card , or E-check (i.e. using your regular Bank Account).
We are PayPal Verified
2) Bank Transfer / Wire Transfer / T/T
Bank Transfer / Wire Transfer / T/T payment methods are accepted for orders which the total price is up to US$300. The bank will charge about US$50 for the transfer fee if we do the payment in these ways. Feel free to contact us for bank payment details if you need pay via bank.
For other payment method, please contact us at orders@icstation-team.com for more details.