DC-DC 50V 5A Adjustable Automatic Buck Power Supply Module CCCV Step Down Voltage Converter LCD Display Voltage Monitor
$15.39$21.9930%
00d : 00h : 00m : 00s
Item ID: GY18199
Product Details
1.Description:
WZ5005L is a DC 50V 5A 250W adjustable constant voltage constant current automatic step down power supply module with LCD display.HD display input voltage and output voltage, current, power, capacity, and time.Adjustable stable output voltage and current.Set output current to meet the demand.It can be used as ordinary buck power supply module, charger and LED constant current driver.Simple and efficient, practical.
2.Features:
1>.DC 55V input work voltage
2>.250W output power
3>.Multiple parameters are displayed simultaneous
4>.Enabled/disabled output
5>.Constant voltage constant current output
6>.Support input anti-reverse protection
7>.Support output anti-backflow protection
8>.Support output over-voltage protection
9>.Support output over-current protection
10>.Support output over power protection
11>.Support input under-voltage protection
12>.Support timeout protection
13>.Support output over-capacity protection
14>.Display input voltage
15>.Display output voltage, current, power
16>.Working status indicator
3.Parameters:
1>.Product Name:WZ5005L 50V 5A Step Down Power Supply Module
2>.Product Number:WZ5005L
3>.Working Voltage:DC 6.0V-55.0V
4>.Output Voltage:DC 0.0V-50.0V
5>.Output Current:5.0A(Max)
6>.Output Power:250W(Max)
7>.Output Voltage Difference:>0.05%+1V
8>.Voltage Display Resolution:0.01V
9>.Current Display Resolution:0.001A
10>.Input Voltage Precision:0.1%
11>.Output Voltage Precision:0.3%
12>.Current Display Precision:0.5%
13>.Output ripple:150mV-PP
14>.Detection capacity range:0.00AH-99.99AH
15>.Capacity display error:2%
16>.Statistical time range:00:00-99:59Hour
17>.Conversion efficiency:About 88%
18>.Input Anti-reverse Protection:Yes
19>.Output Anti-backflow Protection:Yes
20>.Input under-voltage protection:Yes(5.8V-50V Adjustable.Default 5.8V)
21>.Output over-voltage protection:Yes(0V-51V Adjustable.Default 51V)
22>.Output over-current protection:Yes(0V-5.1A Adjustable.Default 5.1A)
23>.Output over power protection:Yes(0V-260W Adjustable.Default 260W)
24>.Timeout protection:Yes(00:00-99:59Hour Adjustable.Default OFF)
25>.Output over-capacity protection:Yes(0.00AH-99.99AH Adjustable.Default OFF)
26>.Working Temperature range:-20℃~40℃
27>.Working Humidity range:0%-95%RH
28>.Size:79*43*58mm
4.Normal Display Mode:
1>.Default normal display.
2>.Short press potentiometer to enabled/disabled output.
3>.Short press SW button to switch display output current A, output power W, output capacity Ah,Statistical time h at the second line.
4>.Keep press SW button about 3second to switch display input voltage and output voltage at the first line.
5>.Short press U/I button enter into adjust output voltage and output current interface.
6>.Keep press U/I button about 3second enter into parameter set interface.
5.Voltage/Current Set Mode:
1>.Short press U/I button to switch select adjust output voltage, output constant current and exit.
2>.Short press potentiometer to switch set bit for select parameters.
3>.Rotary potentiometer to set parameter value. Turn right to increase parameter value and turn left to decrease parameter value.
6.Parameter Set Mode:
1>.Short press SW button to switch set select parameters: OPEN, LVP, OVP, OCP, OPP, OAP, OHP,ZEro, CAL at Parameter Set Mode.
2>.Short press potentiometer to switch set bit for select parameters: OPEN, LVP, OVP, OCP, OPP, OAP, OHP,ZEro, CAL at Parameter Set Mode.
3>.Keep press potentiometer about 3second to turn ON or OFF set parameter which needs ON or OFF.
4>.Rotary potentiometer to set parameter value for OPEN, LVP, OVP, OCP, OPP, OAP, OHP,ZEro, CAL parameters.Turn right to increase parameter value and turn left to decrease parameter value.
5>.Keep press U/I button about 3second to save parameters and return to normal display interface.
7.Setting Method:
1>.Set output voltage:
1.1>.Short press U/I button at normal display mode then one Bit will flashing.
1.2>.Rotary potentiometer to change value for flashing bit.
1.3>.Short press potentiometer to move flashing bit as required.
1.4>.Rotary potentiometer to change value for flashing bit.
1.5>.Repeat rotary and press potentiometer to finish set output voltage.
1.6>.Keep press U/I button about 3second to save parameters and return to normal display interface.
2>.Set output constant current:
2.1>.Short press U/I button at normal display mode.
2.2>.Short press U/I button again and then one Bit will flashing.
2.3>.Rotary potentiometer to change value for flashing bit.
2.4>.Short press potentiometer to move flashing bit as required.
2.5>.Rotary potentiometer to change value for flashing bit.
2.6>.Repeat rotary and press potentiometer to finish set output constant current.
2.7>.Keep press U/I button about 3second to save parameters and return to normal display interface.
3>.Set default power-on state:
3.1>.This function set by parameter OPEN at parameter set mode.
4>.Calibration voltage and current:
4.1>.This function set by parameter Zero and CAL at parameter set mode.
4.2>.Display Zero+OUT+A is used to clear output current display by keep press potentiometer about 3second.
4.3>.Display CAL+IN+V is used to calibration display input voltage by rotary potentiometer to set calibration value.
4.4>.Display CAL+OUT+V is used to calibration display output voltage by rotary potentiometer to set calibration value.
4.5>.Display CAL+OUT+A is used to calibration display output current by rotary potentiometer to set calibration value.
4.6>.Keep press potentiometer to save parameter value and exit.
4.7>.Keep press U/I button about 3second to save parameters and return to normal display interface.
4.8>.Please make sure the voltage is more than 12V in order to ensure the accuracy of calibration.
4.9>.Please make sure the current is more than 1A in order to ensure the accuracy of calibration.
8.Auxiliary Function:
1>.Statistics Capacity and work time:The statistics are started when turn ON output, and the statistics are stopped when the turn ON at next time.
2>.Set Maximum Output Capacity OAP:WZ5005L disabled output and LCD flashing display OAP when Statistics Capacity Value is more than set maximum value OAP if enabled OAP function.Automatically clear capacity statistics after the alarm is cleared.WZ5005L will automatically count whether or not OAP is enabled.But output will not disabled output if disabled OAP function.
4>.Set Maximum Running Time OHP:WZ5005L disabled output and LCD flashing display OHP when Statistics Work Time is more than set maximum value OHP if enabled OHP function.Automatically clear work time statistics after the alarm is cleared.XY-SK80 will automatically count whether or not OHP is enabled.But output will not disabled output if disabled OHP function.It is countdown mode if enabled OHP.
5>.CC and CV display:CC Indicator will turn ON if output current reaches the set current value.
9.Note:
1>.Input undervoltage protection voltage is 5.8V. Module need re-power if input less than 5.8V.
2>.It is a step down converter and so the output voltage must be less than the input voltage and make sure Vout<Vin*0.05%+1V.
3>.It is a DC power module,So it can not connect to AC power.
4>.Please connect input before connect battery when use as charge and make sure output voltage is higher than battery voltage.
5>.’IN-’ and ‘OUT-’ can not be connect together.Otherwise module can not support constant current output.
6>.Please make sure input power is more than load power.
7>.Please step down output power if module is hot.
8>.Please read use manual and description before use.
10.Application:
1>.Ordinary power supply
2>.Battery charger
3>.LED drive power
4>.Instrument voltage display
5>.Test meter
6>.Circuit test
7>.Power conversion
11.Package:
1pcs WZ5005L 50V 5A Step Down Power Supply Module