• DC6V-120V 30A Lead-acid Battery Voltage Monitor, Lithium Battery Charge Discharge Controller Protection Board
  • DC6V-120V 30A Lead-acid Battery Voltage Monitor, Lithium Battery Charge Discharge Controller Protection Board
  • DC6V-120V 30A Lead-acid Battery Voltage Monitor, Lithium Battery Charge Discharge Controller Protection Board
  • DC6V-120V 30A Lead-acid Battery Voltage Monitor, Lithium Battery Charge Discharge Controller Protection Board
  • DC6V-120V 30A Lead-acid Battery Voltage Monitor, Lithium Battery Charge Discharge Controller Protection Board

DC6V-120V 30A Lead-acid Battery Voltage Monitor, Lithium Battery Charge Discharge Controller Protection Board

$6.65
$9.5030%
00d : 00h : 00m : 00s
Item ID: GY21162-1

Product Details

1.Description:
 The battery charging control module is a module that controls the power supply of the charger. It can realize automatic power off after the battery voltage exceeds the preset value.

2.Feature:
 1>.Suitable for 6~120V batteries.
 2>.Set the starting voltage freely.
 3>.Set the stop voltage freely.
 4>.Safe and energy efficient.
 5>.Automatic power off.

3.Parameter:
 1>.Product Name:30A automatic battery charging control module.
 2>.Model:YX-X2202.
 3>.Display Precision:0.1V.
 4>.Control Precision:0.1V.
 5>.Output Type:Switch.
 6>.Voltage Error:+-0.2V.
 7>.Battery Voltage:6~120V(include lead-acid batteries, lithium batteries, polymer batteries and so on).
 8>.Product Load:30A.
 9>.Work Temperature:-25℃~85℃.
 10>.Work Humidity:0%~95%RH.
 11>.Size:93*57mm(H<30mm).

4.Charging Instructions:
 1>.If the battery specification is 6V, the range of charging voltage is 6~7.2V.
 2>.If the battery specification is 12V, the range of charging voltage is 12~14.4V.

 3>.If the battery specification is 24V, the range of charging voltage is 24~28.8V.
 4>.If the battery specification is 36V, the range of charging voltage is 36~43.2V.

 5>.If the battery specification is 48V, the range of charging voltage is 48~57.6V.
 6>.If the battery specification is 60V, the range of charging voltage is 60~72V.

 7>.If the battery specification is 72V, the range of charging voltage is 72~86.4V.
 8>.If the battery specification is 84V, the range of charging voltage is 84~100.8V.

 9>.The charging current should not exceed 1/10 of the electric capacity.
 10>.The charging voltage should not exceed 1.2 times the battery voltage.

5.Voltage Setting:
 1>.The start button can increase the voltage, and the stop button can reduce the voltage.

 2>.Set the starting voltage:
      2.1>.In normal display voltage state, press the start button once to display the start charging voltage.
     2.2>.Press and hold the start button, and adjust the start charging voltage with the start button and stop button after nixie tube flsahes.

 3>.Set the stop voltage:
      3.1>.In normal display voltage state, press the stop button once to display the stop charging voltage.
      3.2>.Press and hold the stop button, and adjust the stop charging voltage with the start button and stop button after nixie tube flsahes.

 4>.Factory data reset:
      4.1>.When powered on, press the start and stop button at the same time.
      4.2>.If 888 is displayed on the nixie tube, the reset is successful.

6.Package:
  1 pcs 30A automatic battery charging control module.

Customer Reviews (0)