DC6V-120V 30A Lead-acid Battery Voltage Monitor, Lithium Battery Charge Discharge Controller Protection Board
Product Details
1.Description:
The battery charging control module is a module that controls the power supply of the charger. It can realize automatic power off after the battery voltage exceeds the preset value.
2.Feature:
1>.Suitable for 6~120V batteries.
2>.Set the starting voltage freely.
3>.Set the stop voltage freely.
4>.Safe and energy efficient.
5>.Automatic power off.
3.Parameter:
1>.Product Name:30A automatic battery charging control module.
2>.Model:YX-X2202.
3>.Display Precision:0.1V.
4>.Control Precision:0.1V.
5>.Output Type:Switch.
6>.Voltage Error:+-0.2V.
7>.Battery Voltage:6~120V(include lead-acid batteries, lithium batteries, polymer batteries and so on).
8>.Product Load:30A.
9>.Work Temperature:-25℃~85℃.
10>.Work Humidity:0%~95%RH.
11>.Size:93*57mm(H<30mm).
4.Charging Instructions:
1>.If the battery specification is 6V, the range of charging voltage is 6~7.2V.
2>.If the battery specification is 12V, the range of charging voltage is 12~14.4V.
3>.If the battery specification is 24V, the range of charging voltage is 24~28.8V.
4>.If the battery specification is 36V, the range of charging voltage is 36~43.2V.
5>.If the battery specification is 48V, the range of charging voltage is 48~57.6V.
6>.If the battery specification is 60V, the range of charging voltage is 60~72V.
7>.If the battery specification is 72V, the range of charging voltage is 72~86.4V.
8>.If the battery specification is 84V, the range of charging voltage is 84~100.8V.
9>.The charging current should not exceed 1/10 of the electric capacity.
10>.The charging voltage should not exceed 1.2 times the battery voltage.
5.Voltage Setting:
1>.The start button can increase the voltage, and the stop button can reduce the voltage.
2>.Set the starting voltage:
2.1>.In normal display voltage state, press the start button once to display the start charging voltage.
2.2>.Press and hold the start button, and adjust the start charging voltage with the start button and stop button after nixie tube flsahes.
3>.Set the stop voltage:
3.1>.In normal display voltage state, press the stop button once to display the stop charging voltage.
3.2>.Press and hold the stop button, and adjust the stop charging voltage with the start button and stop button after nixie tube flsahes.
4>.Factory data reset:
4.1>.When powered on, press the start and stop button at the same time.
4.2>.If 888 is displayed on the nixie tube, the reset is successful.
6.Package:
1 pcs 30A automatic battery charging control module.