• DC 5V-30V Multi-Function Trigger Cycle Timer MOS Delay Controller Module Power-ON Control Switch
  • DC 5V-30V Multi-Function Trigger Cycle Timer MOS Delay Controller Module Power-ON Control Switch
  • DC 5V-30V Multi-Function Trigger Cycle Timer MOS Delay Controller Module Power-ON Control Switch
  • DC 5V-30V Multi-Function Trigger Cycle Timer MOS Delay Controller Module Power-ON Control Switch
  • DC 5V-30V Multi-Function Trigger Cycle Timer MOS Delay Controller Module Power-ON Control Switch
  • DC 5V-30V Multi-Function Trigger Cycle Timer MOS Delay Controller Module Power-ON Control Switch

DC 5V-30V Multi-Function Trigger Cycle Timer MOS Delay Controller Module Power-ON Control Switch

$4.68
$6.6930%
00d : 00h : 00m : 00s
Item ID: GY20754-1

Product Details

1.Description:
   Multi-function time relay module, 5~30V wide voltage power supply, MOS tube control output, no contact, no ignition, little interference. Up to 10A control capability.

  There are up to 31 working modes to meet various testing and automatic control applications. The delay time is adjustable from 0.01 second to 999 minutes. The trigger port can be triggered by a voltage signal or by connecting a button.

2.Feature:
  1>.Support reverse connection protection
  2>.Continuously adjustable from 0.1 seconds to 999seconds
  3>.4 digit digital tube display
  4>.Programmable working mode
 
3.Parameter:
  1>.Power supply voltage: 5~30V
  2>.Trigger terminal voltage: DC 3.3~30V(can also be triggered by button)
  3>.Maximum control current: 10A
  4>. Work Temperature: -25℃~85℃
  5>.Work Humidity: 5%~95%RH
  6>.Size:63*42*14mm

4.Instructions for use:
  1>.Setting of working parameters: Press and hold the S1 button without letting go, the display will show P-xx after 0.5 seconds, press S2 and S3 to change the working mode;

  2>. After selecting the working mode, short press the S1 key to enter the A time setting, and the screen displays Axxx. At this time, press the S2 and S3 keys to modify the A time parameter. Short press the S2 and S3 keys to add or subtract 1, and long press to quickly add or subtract 10. Press the S4 key to set the position of the decimal point;

  3>.After setting the A time, press the S1 key to set the B time, and the screen displays bxxx. At this time, press the S2 and S3 keys to modify the B time parameter. Short press the S2 and S3 keys to add or subtract 1, and long press to quickly add or subtract 10. Press the S4 key to set the position of the decimal point;

  4>.After setting the B time, press the S1 key to set the C time, the screen displays Cxxx, at this time press the S2 and S3 keys to modify the c time parameter, short press the S2 and S3 keys to add or subtract 1, long press to quickly add or subtract 10, Press the S4 key to set the position of the decimal point;

 5>.After setting the c time, press the S1 key to enter the most setting of the d parameter. The d parameter is the number parameter, ranging from 1 to 999. After setting the d parameter, press the S1 key one last time to exit the setting state and save all parameters.

5.The meaning of the decimal point position:
  1>.Ax.xx The decimal point is in hundreds, the timing range is 0.01~9.99 seconds
  2>.Axx.x The decimal point is in tens place,the timing range is 0.1~99.9 seconds
  3>.Axxx. The decimal point is in the ones place, the timing range is 1~999 seconds
  4>.Axxx has no decimal point and the time range is 1~999 minutes
  5>.Turn off the display: In the non-setting state, press the S4 key to turn off the display, and then press it to turn it on again.
 
6.Working mode:
  1>.P-01: The relay is disconnected after power-on or triggered, and the relay is closed after a delay of time A

  2>.P-02: Closed after power-on or triggered, the relay is disconnected after a delay of A time

  3>.P-03: Jog mode, pull-in with signal, disconnect without signal

  4>.P-04: Self-locking mode, the relay state flips once after each trigger

  5>.P-05: After triggering, the relay pulls in and stops after a delay of A time. Repeated triggering is not allowed during the delay

  6>.P-06: After triggering, the relay is closed, and it stops after a delay of A time. Repeated triggering during the delay period will re-timing

  7>.P-07: After triggering, the relay will pull in, and stop after a delay of A seconds. Repeat triggering during the delay period, and the time will accumulate

  8>.P-08: After triggering, the relay is closed, and it will stop after a delay of A second, and it will stop immediately after triggering again during the delay.

  9>.P-09: After triggering, the relay is closed. After the signal disappears, the delay will stop for A second, and the trigger will restart during the delay.

  10>.P-10: After power-on, pull-in time A, disconnect time B, infinite loop

  11>.P-11: When there is a continuous signal, pull in for A time, disconnect for B time, infinite loop, stop immediately when the signal disappears
  12>.P-12: Trigger once, pull in A time, disconnect B time, infinite loop, trigger again to stop

  13>.P-13: The relay is closed when the power is on, the relay is disconnected after triggering, and the relay is closed after a delay of time A

  14>.P-14: There is a continuous signal, the relay is closed after the time A exceeds, and the signal disappears and the relay is disconnected

 15>.P-15: The relay with continuous signal is disconnected, and the relay is closed after the signal disappears for more than A time

16>.P-16: The relay is closed after a continuous signal exceeds the A time, and the relay is disconnected after the signal disappears for more than A time

  17>.P-17: The relay is closed after a continuous signal exceeds the A time. After the signal disappears, the relay is disconnected after the continuous signal exceeds the A time.

  18>.P-18: Triggered, the relay is closed after time A is exceeded, and triggered again, the relay is disconnected after time A is exceeded

  19>.P-19: There is a continuous signal that the relay pulls in for A time and then stops, and then if the signal disappears, the relay pulls in for A time and then stops

  20>.P-20: There is pulse signal (rising edge or falling edge), the relay stops, and there is no pulse signal, the relay will be closed after a delay of A time (continuous high level or continuous low level is considered as no pulse)

  21>.P-21: After power-on, the relay will be closed after the delay time A, and stop after the time B is closed

  22>.P-22: After triggering, the relay will be closed after delaying time A, and stop after closing time B

  23>.P-23: There is a continuous signal and the relay is closed after the time A is exceeded, and it stops after the time B is closed

  24>.P-24: After triggering, the relay stops after the time A is closed, and then counts the time B after it stops. It cannot be triggered again within the time A+B

  25>.P-25: After triggering, the relay stops after closing A time, timing B time, and then closing A time and then stop. During this time, it cannot be triggered repeatedly

  26>.P-26: Counting mode, rising edge trigger, every time a rising edge is detected, the value is +1, the maximum count is 9999, the maximum frequency is 20Hz, short press the S1 key to clear

  27>.P-27: Counting mode, falling edge trigger, each time a falling edge is detected, the value is +1, the maximum count is 9999, the maximum frequency is 20Hz, short press the S1 key to clear

  28>.P-28: Counting mode, rising edge trigger value +1, maximum 9999, MAX 20Hz, when the count value is equal to the d parameter, the relay is closed and the program stops. Press the S1 button at any time to reset

  29>.P-29: Counting mode, rising edge trigger value +1, maximum 9999, MAX 20Hz, when the count value is equal to the d parameter, the program will automatically reset after the relay pulls in for A time. Press the S1 button at any time to reset

  30>.P-30: After the trigger, delay time A and then pull in (falling edge trigger), pull in after B time, disconnect, count once, stop when the number of counts reaches the d parameter, if there is a trigger (rising) during the A time delay Edge) will reset

  31>.P-31: After power-on, count down c time and then automatically trigger. After triggering, it will delay time A and then pull in, pull in after B time, disconnect, count once, when the number of counts reaches the d parameter, a new cycle will be restarted

7.Package:
  1pcs DC 5V-30V Multi-Function Trigger Cycle Timer MOS Delay Controller Module.